EVVA DPS

From Lockwiki
Revision as of 16:44, 1 December 2009 by Datagram (talk | contribs)
Jump to navigationJump to search

EVVA DPS/DPX

EVVA DPS/DPX
EVVA DPI cylinder.jpg
Name EVVA DPS/DPX
Manufacturer EVVA
Lock Type Cylinder
Lock Design Pin-tumbler, Sidebar
Year(s) Produced 1996-Present
Patent US 5,797,287


The EVVA DPS (Double Profile System) is a five or six pin-tumbler lock made by EVVA. The DPS uses a single sidebar for key profiling, located at the 4 o'clock position.

The EVVA DPX (Double Profile eXtended) is a newer form of the DPS that provides two key-profiling sidebars in addition to the pin-tumbler components. Sidebars are located on each side of the plug, in the 4 and 8 o'clock positions. The DPX is also marketted as the Mottura PX in Europe.

Both the DPS and DPX have been superseded by the EVVA DPI to protect against key bumping attacks.

Principles of Operation

The DPS and DPX are traditional pin-tumblers with the addition of a key-profiling sidebar. In the case of the DPX, there are two sidebars that provide key-profiling.

In both cases the pin-tumblers function normally, and profile cuts on the side(s) of the key interface with the sidebar(s). The sidebar is active, and the center portion must be aligned properly or the third driver (top) pin will function as a trap pin when the plug is rotated.[1]

Disassembly instructions

  1. Remove the cam and C-clip.
  2. Insert the key and turn the plug 30-45 degrees in either direction.
  3. Slowly withdraw the plug from the cylinder.

Notes

  • The plug may be difficult to remove at any 90 degree orientation because of the trap pin; 45 degree angles are recommended.
  • The trap pin is beveled so it cannot fall out when removing the plug.

Vulnerabilities

The DPS/DPX may be vulnerable to one or more of the following:

Gallery

References

See also