== Disassembly instructions ==
== Disassembly instructions ==


Add to me!
Due to the atypical construction of this lock, disassembly using a follower is not recommended.
 
# Remove the Torx screw on the tailpiece and the wafer beneath it.
# Unscrew the retaining cap on the rear of the plug.
# Unscrew and remove the closing rod over the pin chambers (be careful not to allow springs to escape).
# Remove the driver pins and springs. They are all the same so there is no need to keep them in order. Key pins cannot fit through the top chambers.
# Slide the plug out of the housing.


== Vulnerabilities ==
== Vulnerabilities ==

Revision as of 18:32, 17 March 2019

ASSA d12

ASSA d12
Assa d12 front.jpg
Name ASSA d12
Manufacturer ASSA-Abloy
Lock Type Cylinder
Lock Design Pin-tumbler


The d12 is a medium security pin tumbler made by ASSA for residential or commercial use. It is intended as a successor to the ASSA 700 series which dates back to 1948. It features six pins and numerous security improvements over the original cylinder, including a paracentric keyway and patented key profiles.


Principles of operation

Add to me!

Disassembly instructions

Due to the atypical construction of this lock, disassembly using a follower is not recommended.

  1. Remove the Torx screw on the tailpiece and the wafer beneath it.
  2. Unscrew the retaining cap on the rear of the plug.
  3. Unscrew and remove the closing rod over the pin chambers (be careful not to allow springs to escape).
  4. Remove the driver pins and springs. They are all the same so there is no need to keep them in order. Key pins cannot fit through the top chambers.
  5. Slide the plug out of the housing.

Vulnerabilities

The ASSA d12 may be vulnerable to one or more of the following: